Short Path Condenser Manufacturer,Supplier and Exporter in India
Product Code : SCL-GC-10328
The Short Path Condenser 12L / 22L is a laboratory condenser component used for condensing vapours in compatible short-path distillation, vapour-transfer, and recovery assemblies. This condenser is specified with a 34/45 joint and is intended for compatible 12L and 22L laboratory glassware systems.
Product Description
The N 12L & 22L Short Path Condenser - 34/45 from Lab Glassware Manufacturer is intended for laboratory setups where vapour must travel through a short, controlled path before condensation and collection. The confirmed product data identifies the product as a short path condenser for 12L and 22L compatible systems with a 34/45 joint reference.
A short path condenser is useful in chemistry, research, and preparation-room workflows where vapour routing, condensation, and joint compatibility are important. Exact glass type, condenser length, jacket design, hose-connection size, coolant compatibility, vacuum suitability, and certification status should be confirmed before final catalogue publication.
Key Features
- Short path condenser design: supports compact vapour travel in compatible distillation assemblies.
- 12L and 22L setup reference: listed for compatible 12L and 22L laboratory glassware systems.
- 34/45 joint reference: intended for connection with matching 34/45 jointed glassware.
- Vapour-condensing function: helps convert compatible vapour into liquid condensate when properly cooled.
- Laboratory condenser category: suitable for chemistry, teaching, research, and preparation-room setups.
- Capacity note: 12L and 22L refer to listed setup compatibility, not confirmed condenser internal volume.
- Specification-dependent use: vacuum, coolant, thermal, and chemical compatibility must be verified.
Technical Specifications
|
Specification |
Detail |
|
Product Name |
N 12L & 22L Short Path Condenser - 34/45 |
|
Primary Keyword |
Short Path Condenser 12L / 22L |
|
Secondary / Semantic Keywords |
short path condenser, 34/45 condenser, laboratory distillation condenser, vapour condenser glassware, 12L condenser assembly, 22L condenser assembly, short path distillation glassware, laboratory glass condenser |
|
Brand / Supplier |
Lab Glassware Manufacturer |
|
Product Category |
Laboratory Glassware / Glass Condenser / Short Path Distillation Condenser |
|
Capacity / Setup Reference |
12L and 22L |
|
Design Type |
Short path condenser |
|
Joint Reference |
34/45 |
|
Intended Users |
Universities, chemistry labs, organic chemistry labs, research labs, pharmaceutical labs, testing labs, exporters, distributors, and procurement teams |
What's Included in the Kit
- Short Path Condenser 12L / 22L with 34/45 joint
- Joint clips, hose connectors, receiving flask, distillation head, adapters, clamps, storage case, or certificate
Applications / Uses
- Condensing vapours in compatible short-path distillation assemblies
- Supporting solvent recovery, vapour transfer, and condensate collection workflows
- Connecting compatible 34/45 jointed laboratory glassware
- Use with 12L and 22L compatible distillation systems where verified
- Teaching distillation and condensation principles in advanced chemistry laboratories
- Supporting research, pharmaceutical, testing, and preparation-room glassware setups
How to Use the N 12L & 22L Short Path Condenser
- Confirm that the 34/45 joint matches the connected distillation head, receiver, or glassware assembly.
- Inspect the condenser for cracks, chips, scratched joints, blocked vapour paths, or damaged hose connections.
- Clean and dry all mating joints before assembly.
- Install the condenser in the approved orientation for the short-path setup.
- Secure the complete assembly using suitable stands, clamps, and joint clips before operation.
- Connect coolant tubing to the correct inlet and outlet after confirming hose size and flow direction.
- Run coolant flow before heating, then operate only within verified temperature, pressure, and vacuum limits.
- Allow the condenser and connected glassware to cool before disassembly, cleaning, and storage.
Safety note: Do not use this condenser with vacuum, pressure, flammable solvents, hazardous vapours, hot fluids, or low-temperature cooling unless the glass type, joint integrity, coolant compatibility, and complete apparatus rating are verified. Use eye protection, gloves, clamps, and a fume hood where required.
Care & Maintenance
- Flush the condenser after use with a cleaning method suitable for the verified glass and residue.
- Drain and dry coolant passages before storage to reduce residue and contamination.
- Store in padded glassware storage to protect joints, jacket tubes, and hose connectors.
- Remove from service if cracks, chips, leaks, blocked passages, or stressed glass areas are visible.
Why Choose Lab Glassware Manufacturer
Lab Glassware Manufacturer manufactures and exports laboratory glassware, scientific laboratory instruments, lab experiment setups, science kits, didactic models, and STEM learning products. The brand serves schools, colleges, universities, laboratories, exporters, and institutional procurement buyers. Its product catalogue supports chemistry, biology, physics, laboratory glassware supply, and education-focused scientific experimentation.
Frequently Asked Questions
What is a Short Path Condenser 12L / 22L used for?
A Short Path Condenser 12L / 22L is used for condensing vapours in compatible short-path distillation, solvent-recovery, and vapour-transfer glassware assemblies.
What does 34/45 mean on this condenser?
34/45 is the confirmed joint reference from the supplied product name. It should be connected only to compatible 34/45 jointed laboratory glassware.
Do 12L and 22L mean condenser capacity?
The supplied product name lists 12L and 22L, but it does not confirm whether these refer to condenser volume, flask compatibility, or system size. Confirm this before final specification use.
Is this condenser made from borosilicate glass?
The supplied product name does not confirm the material. Add borosilicate glass, quartz, or other material claims only after verification.
Can this condenser be used under vacuum?
Vacuum suitability is not confirmed. Use under vacuum only if the condenser, joints, wall thickness, and complete apparatus are rated for that condition.
Does this product include tubing or clamps?
The confirmed item is the Short Path Condenser 34/45. Tubing, clamps, joint clips, adapters, and receiving glassware should be listed only after verifying the supplied configuration.
For related condenser and laboratory glassware products, explore laboratory glass condensers, glass condenser products, glassware adapters, and laboratory glass joints.